  • Can be easily added to control
    any G2 heat exchanger
  • Volt free heat output contact for
    heating appliance control
  • Grundfos Logo 
    Booster Pump
  • Flow Switch

ELECRO

G2 Fully Equipped Kit Options


  • Can be easily added to control any G2 heat exchanger
  • Digital control thermostat with Priority heating feature,
    temperature display & 0.5°C differential, OR
  • Analogue control thermostat (simple easy to use) with 1.5°C differential
  • Volt free heat output contact for heating appliance control
  • Grundfos booster pump
  • Flow switch, ensuring your heating appliance is only switched on
    when the pool circulation pump is running

The Elecro G2 heat exchanger has been designed to allow a very simple and easy to fit equipped upgrade kit that incorporates a thermostat control system. The equipped kits are suitable for any of the G2 power outputs and can be retro fitted if required.

There are two thermostat control options:
The sophisticated digital control thermostat that displays the current water temperature
with a 0.5°C differential, features a priority heating function that allows the unit
to control the circulation pump and a visual no flow alarm.
Or
The simpler "set and forget” analogue control thermostat with a 1.5°C differential.

The Equipped kits are supplied complete with:

Digital Kit Analogue Kit

Digital control thermostat
(0.5°C differential and
features Priority heating)

Analogue control thermostat
(1.5°C differential)
Grundfos Logo booster pump Grundfos Logo booster pump
Flow switch (with gold tipped reed switch) Flow switch (with gold tipped reed switch)
1" female / female brass fitting 1" female / female brass fitting
NTC temperature sensor

Clcik Here To Download
Download Product Data Sheet

Tube bundle Pure Titanium
Water connections 1½" or 50-mm rigid pipe
Heating circuit connections 1" BSP
Maximum operating pressure 4 barg
Mounting Floor or wall mountable

Product Codes
Digital Equipped Kit Product Code Analogue Equipped Kit Product Code
G2-HE-DIG G2-HE-ANA

Standard Power Output Primary (HOT) Flow (m³/h) Primary (HOT) Head Loss (kpa) Secondary (POOL) Flow (m³/h) Secondary (POOL) Head Loss (kpa) ΔT 15ºC (kW) ΔT
20ºC (kW)
ΔT
30ºC (kW)
ΔT
40ºC (kW)
ΔT 50ºC (kW) ΔT 60ºC (kW) ΔT 70ºC (kW)
30-kW 1.1 6.1 10 5.0 9 11 16 20 26 30 33
30-kW 1.3 6.8 10 5.0 10 13 18 23 31 34 39
30-kW 1.3 6.8 14 7.0 11 15 20 26 34 41 46
49-kW 1.6 7.7 16 9.2 13 18 25 34 41 50 56
49-kW 1.8 8.3 16 9.2 14 20 28 38 45 55 62
49-kW 2.2 9.6 17 9.8 16 22 33 44 52 64 73
85-kW 2.4 11.3 17 10.6 22 28 40 53 64 75 81
85-kW 2.7 12.9 17 10.6 26 32 46 60 73 82 89
85-kW 3.2 14.7 17 10.6 28 34 49 64 77 90 102
122-kW 3.8 18.3 19 12.6 33 43 68 75 93 108 120
122-kW 4.2 20.0 19 12.6 36 48 70 89 108 126 143
122-kW 4.6 21.1 19 12.6 38 52 73 95 116 137 156

ΔT = Temperature difference between Primary (HOT) and Secondary (POOL)

To calculate BTU multiply kW x 3412
kW x 3412 = BTU Output

For dimension 'L' please refer to models tab, all other measurements in mmElecro G2 Equipped Heat Exchanger Dimensions

Horizontal Installation

Elecro Heat Exchnager Schematic Diagram

Vertical Installation

Elecro Heat Exchnager Vertical Schematic Diagram

Similar products that may be of interest:

 
G2 Heat Exchanger

View
 
  • Vast, unrivalled heat transfer surface area
  • Titanium tube bundle
  • Robust, durable construction
  • Available in 30-kW (102K BTU)
    > 122-kW (416K BTU)
  • Available with fully equipped
    Analogue or Digital control (optional)